4 Installation PowerRouter • Solar Inverter • Installation manual
18
EN
4 Installation
4.1 Check the contents of the PowerRouter box
The PowerRouter box must contain the following:
• The PowerRouter.
• Wall-mounting bracket.
• Set of manuals, including the drill template.
• Clip-on ferrite core for the UTP cable (Internet).
• Cable gland (for installation in Italy).
• Clip-on ferrite core for the digital input (for installation in Italy).
4.2 Determine the mounting location
The installation location of the PowerRouter must meet the following:
• The PowerRouter must be mounted indoors.
• Mount the PowerRouter as close as possible to the meter cupboard.
• Do not mount the PowerRouter in direct sunlight.
• Do not mount the PowerRouter during periods of precipitation or high humidity (>95%). Moisture
trapped within the location may cause corrosion and damage to the electronic components.
• When the internal temperature is too high, derating will occur. The PowerRouter reduces the power
output if the internal temperature becomes too high.
• The location is not accessible for children.
• The PowerRouter emits a slight hum during operation. This noise is normal and has no effect on
performance, but it can be disturbing if the unit is installed on a wall in a living area, on the outside of
a wall that is near a living area, or on certain types of materials (thin wood panels or sheet metal).
• The wall should be within ± 5° vertical.
• The mounting surface must be able to support the weight of the PowerRouter (15.5 kg).
• The type information sticker must be visible after mounting the PowerRouter (figure 1). The sticker
contains the serial number which is the login code for the install wizard, the software installation tool
and to register at www.myPowerRouter.com for logging and monitoring.
• The outside dimensions of the PowerRouter are 545 x 502 x 149 mm (W x H x D).
• The PowerRouter must be installed with 300 mm clearance at the top and bottom of the unit.
• If multiple PowerRouters are stacked theclearance between each PowerRouter must be 800 mm.