14
SCREENGUARD
™
INSTALLATION AND USER MANUAL
INSTALLATION
A
D
B
B
C
Hydraulic installation
Ensure the direction of flow is according to
the arrows marked on the filter inlet and outlet.
Flanged models: Place gaskets on the inlet and outlet flanges (B).
Threaded models: Aplly Teflon tape to the threads.
Position the filter in place.
Threaded models: Tighten the inlet and outlet connectors.
Flanged models: Fasten the inlet and outlet flanges bolts.
Connect a pipe (C) to the port (D).
Water should be allowed to flow
to the atmosphere freely from the
flush pipe.
Secure the open end of the flush pipe to prevent movement during the flushing cycle.
Avoid placing the flush pipe on a rising slope to prevent backpressure.
ATTENTION
The inlet pipe should be of a diameter equal to or larger than the filter inlet diameter.
Never connect a the SG filter to an inlet pipe of a diameter smaller than the filter inlet diameter.
ATTENTION
If a PRV is required in order to protect the irrigation system, it is highly recommended to install it
downstream of the filter.
Diameter Length
2" up to 10 m
3" 10-20 m (maximum 20m)
Inlet Outlet