98
5-34 ABORT
Aborts the process being performed by the PC and enables reception of the next
command. There is no response.
Command Format
@ XZ
Unit no. FCS TerminatorHeader
code
*s
x 10
0
x 10
1
Note The PC requires 100 ms between reception of the ABORT command and the
following command.
5-35 Response to an Undefined Command
This response is sent if the PC cannot decode the header code of the command.
If this response is received, check the header code that was sent in the previous
command block.
Response Format
@ IC
Unit no. FCS TerminatorHeader
code
*s
x 10
0
x 10
1
5-36 INITIALIZE
Initializes all Units in the network. This command does not required the node
number or an FCS. No response format involves. It is possible to use this com-
mand only when the PC is mounted with the Host Link Unit.
*
@
*
s
Note Do not sent the node number or an FCS with the INITIALIZE command.
Caution This command is supported only by CPUs of version 2 or later or by Host Link
Units.
INITIALIZE Section 5-36

Table of Contents

Other manuals for Omron CV500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron CV500 and is the answer not in the manual?

Omron CV500 Specifications

General IconGeneral
BrandOmron
ModelCV500
CategoryController
LanguageEnglish

Related product manuals