28
• Input and Display Values
Input type Setting range Default
DC voltage input –19999 to 99999
Input value 2 199.99
Display value 2 199.99
Input value 1 –199.99
Display value 1 –199.99
DC current input –19999 to 99999
Input value 2 199.99
Display value 2 199.99
Input value 1 –199.99
Display value 1 –199.99
AC voltage input –19999 to 99999
Input value 2 400.0
Display value 2 400.0
Input value 1 0.0
Display value 1 0.0
AC current input –19999 to 99999
Input value 2 10.000
Display value 2 10.000
Input value 1 0.000
Display value 1 0.000
• Decimal Point Position
Input type Setting range Default
DC voltage input
%%%%% (without decimal point)
%%%.%%
DC current input
%.%%%%
%%%.%%
AC voltage input
%%.%%%
%%%%.%
AC current input
%%%.%%
%%%%.%
%%.%%%
Refer to 5-1 Teaching Function for scaling the Process Meter with the sensor
connected.
Follow the steps described below to input the following.
Input value 2 = “5.00”
Display value 2 = “1000.0”
Input value 1 = “1.00”
Display value 1 = “0.0”
Decimal point position = “– – – – . –”
Set Value LED Display Model Basic Model
1, 2, 3... 1. Press the Mode Key for more than one second while the scale scaling menu
is displayed. The inp.2 input value 2 setting will appear.
Set Value LED Display Model Basic Model
SETTING
REFERENCE
SETTING
EXAMPLE
Setting Mode