EasyManuals Logo
Home>Omron>Measuring Instruments>K3NX

Omron K3NX User Manual

Omron K3NX
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
46
Hysteresis
The hysteresis can be set in the option menu to prevent chattering of the out-
put if the measured value fluctuates in the vicinity of the setting values.
The hysteresis can be set within a range of 1 and 9999 digits for four consecu-
tive digits beginning with the leftmost digit regardless of the decimal point.
The value set to 0 is regarded as 1.
The decimal point position set in the scaling menu becomes valid.
Setting range Unit Default
1 to 9999
--- 1
If the comparative output is a level output, however, the hysteresis will be en-
abled when the measured value starts to become smaller than the HH, H, LL,
and L setting values.
Measured value
H setting value
L setting value
H comparative output
L comparative output
Hysteresis
Hysteresis
This setting is only available for the K3NX with the Comparative Output Unit.
Follow the steps described below to set the hysteresis to 30.
Set Value LED Display Model Basic Model
1, 2, 3... 1. Press the Mode Key for more than one second while the opt option menu is
displayed. The aUg average processing setting will appear.
Set Value LED Display Model Basic Model
hys
FUNCTION
SETTING
REFERENCE
MODELS
SETTING
EXAMPLE
Setting Mode
Section 3-2
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents

Other manuals for Omron K3NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron K3NX and is the answer not in the manual?

Omron K3NX Specifications

General IconGeneral
BrandOmron
ModelK3NX
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals