3-2-6 Option Menu (opt)
Average Processing
The average processing of inputs are enabled for setting.
Average processing prevents the display from fluctuating due to unstable in-
put.
Select simple average processing or movement average processing and the
number of sampling times.
Setting Default
1: No average processing
m0002: Movement average processing by sampling 2 times
m0004: Movement average processing by sampling 4 times
m0008: Movement average processing by sampling 8 times
m0016: Movement average processing by sampling 16 times
m0032: Movement average processing by sampling 32 times
s0002: Simple average processing by sampling 2 times
s0004: Simple average processing by sampling 4 times
s0008: Simple average processing by sampling 8 times
s0016: Simple average processing by sampling 16 times
s0032: Simple average processing by sampling 32 times
1
aUg
FUNCTION
SETTING
Setting Mode
Section 3-2
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents

Other manuals for Omron K3NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron K3NX and is the answer not in the manual?

Omron K3NX Specifications

General IconGeneral
BrandOmron
ModelK3NX
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals