59
Setting Value Change Prohibit
• The setting value change of the K3NX in RUN mode with the front panel key
inputs can be prohibited in the protect menu.
Setting Default
kpon: Key protect ON
kpoff: Key protect OFF
kpoff
Refer to 4-2 Checking and Changing Setting Values.
This setting is only available for the K3NX with the Comparative Output Unit.
Follow the steps described below to set the setting value change prohibit to ON.
Set Value LED Display Model Basic Model
1, 2, 3... 1. Press the Mode Key for more than one second while the prot protect menu
is displayed. The all all key protect setting will appear.
Set Value LED Display Model Basic Model
2. Press the Mode Key to display the sUset setting value prohibit setting.
Set Value LED Display Model Basic Model
3. Press the Shift Key to display the prior setting kpoff for changing. The
PROG indicator will flash.
Set Value LED Display Model Basic Model
sUset
FUNCTION
SETTING
REFERENCE
MODELS
SETTING
EXAMPLE
Protect Mode
Section 3-3