95
Appendix A
Specifications
Ratings
Supply voltage 100 to 240 VAC (50/60 Hz); 12 to 24 VDC
Operating voltage
range
85% to 110% of supply voltage
Power consumption
(see note)
15 VA max. (max. AC load with all indicators lit)
10 W max. (max. DC load with all indicators lit)
Sensor power supply 80 mA at 12 VDC±10% (Use a power supply of less than 50 VAC or 70 VDC for input
signals.)
Insulation resistance 20 M min. (at 500 VDC) between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
Dielectric withstand
voltage
2,000 VAC for 1 min between external terminal and case.
Insulation provided between inputs, outputs, and power supply.
Noise immunity ±1,500 V on power supply terminals in normal or common mode ±1 µs, 100 ns for
square-wave noise with 1 ns
Vibration resistance Malfunction: 10 to 55 Hz, 0.5-mm for 10 min each in X, Y, and Z directions
Destruction: 10 to 55 Hz, 0.75-mm for 2 hrs each in X, Y, and Z directions
Shock resistance Malfunction: 98 m/s
2
(10G) for 3 times each in X, Y, and Z directions
Destruction: 294 m/s
2
(30G) for 3 times each in X, Y, and Z directions
Ambient temperature Operating: 10°C to 55°C (with no icing)
Storage: 20°C to 65°C (with no icing)
Ambient humidity Operating: 25% to 85% (with no condensation)
Ambient atmosphere Must be free of corrosive gas
EMC Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
Immunity ESD: EN61000-4-2:4-kV contact discharge (level 2)
8-kV air discharge (level 3)
Immunity-RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz to
1 GHz) (level 3)
10 V/m (pulse modulated, 900 MHz)
Immunity Conducted Disturbance:ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2-kV power-line (level 3)
2-kV I/O signal-line (level 4)
Approved standards UL508, CSA22.2; conforms to EN50081-2, EN50082-2, EN61010-1 (IEC61010-1); conforms
to VDE106/part 100 (Finger Protection) when the terminal cover is mounted.
Weight Approx. 400 g
Note An Intelligent Signal Processor with DC supply voltage requires approximately 1 A DC as control power
supply current the moment the Intelligent Signal Processor is turned on. Do not forget to take this into con-
sideration when using several Intelligent Signal Processors. When the Intelligent Signal Processor is not in
measuring operation (e.g., the Intelligent Signal Processor has been just turned on or is operating for start-
up compensation time), the display will read 00000 and all outputs will be OFF.
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr

Table of Contents