6-52
6-7 Object Dictionary
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
6
Drive Profile
 This object indicates the supported operation modes.
Bit Descriptions
Reserved Objects
The following objects are reserved. Do not use them.
6502 hex
Supported drive modes
Range − Unit − Default
0000 0080
hex
Attribute −
Size 4 bytes (U32) Access RO PDO map Not possible
All
Bit Supported mode Definition
0 pp (Profile position mode) 0: Not supported
1 vl (Velocity mode) 0: Not supported
2 pv (Profile velocity mode) 0: Not supported
3 tq (Profile torque mode) 0: Not supported
4 Reserved: 0
5 hm (Homing mode) 0: Not supported
6 ip (Interpolated position mode) 0: Not supported
7 csp (Cyclic synchronous position mode) 1: Supported
8 csv (Cyclic synchronous velocity mode) 0: Not supported
9 cst (Cyclic synchronous torque mode) 0: Not supported
10 to 31 Reserved 0
Index Sub Name
605D hex 0 Halt option code
6067 hex 0 Position window
6083 hex 0 Profile acceleration
6084 hex 0 Profile deceleration
6099 hex
Homing speeds
0 Number of entries
1 Speed during search for switch
2 Speed during search for zero

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC G5 Series and is the answer not in the manual?

Omron OMNUC G5 Series Specifications

General IconGeneral
BrandOmron
ModelOMNUC G5 Series
CategoryServo Drives
LanguageEnglish

Related product manuals