EasyManuals Logo
Home>Omron>Servo Drives>OMNUC G5 Series

Omron OMNUC G5 Series User Manual

Omron OMNUC G5 Series
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #307 background imageLoading...
Page #307 background image
7
7-22
7-7 Torque Limit Switching
OMNUC G5-series AC Servomotors and Servo Drives User’s Manual (with Built-in EtherCAT Communications)
Applied Functions
Torque Limits in Position Control Mode or Fully-closed Control Mode
The term Torque FF refers to the torque feed-forward function.
*1. When either the external input signal (PCL or NCL) or the EtherCAT communications torque control
command (P-CL or N-CL) is ON.
*2. When both the external input signal (PCL or NCL) and the EtherCAT communications torque control
command (P-CL or N-CL) are OFF.
Torque Limit Settings by Servomotors
 The torque limit setting range is between 0% and 300%. The default setting is 300%. This is not
the case when a Servo Drive and a Servomotor are used in the following combinations.
Set
value
Position Control/Fully-closed Control
Forward torque limit value Reverse torque limit value
Torque FF
PCL ON
*1
PCL OFF
*2
NCL ON
*1
NCL OFF
*2
0,1 60E0 hex
Disabled
2 60E0 hex 60E1 hex
3 60E1 hex 60E0 hex 60E1 hex 60E0 hex
4
60E0 hex 60E1 hex
5
6 3525 hex 60E0 hex 3526 hex 60E1 hex
7 60E0 hex 3525 hex 60E1 hex 3526 hex
Servo Drive
Applicable
Servomotor
Maximum torque limit
[%]
R88D-KN15@-ECT-R R88M-K90010@ 225

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC G5 Series and is the answer not in the manual?

Omron OMNUC G5 Series Specifications

General IconGeneral
BrandOmron
ModelOMNUC G5 Series
CategoryServo Drives
LanguageEnglish

Related product manuals