4-1SectionSpecifications
66
4-1 Specifications
4-1-1 General Specifications
All general specifications of the C200H-MAD01 Analog I/O Unit conform to
those of the C200H, C200HS, and C200HX/HG/HE Series.
4-1-2 Performance Specifications
Item
C200H-MAD01
Voltage I/O Current I/O
Input
Number of analog inputs 2
p
Input signal range (note
1)
0 to 10 V
–10 to 10 V
1 to 5 V
4 to 20 mA
Max. input signal (note 2) ±15 V ±30 mA
Input impedance 1 M min. 250 (rated value)
Resolution 1/4000 (full scale)
Converted output data 16-bit binary data
Accuracy
(note 3)
23°±2°C
±0.2% of full scale ±0.4% of full scale
(note 3)
0° to
55
°C
±0.4% of full scale ±0.6% of full scale
Output
Number of analog outputs 2
p
Output signal range (note
1)
0 to 10 V
–10 to 10 V
1 to 5 V
4 to 20 mA
Output impedance 0.5 max. ---
Max. output current 12 mA ---
Max. load resistance --- 600 max. (note 5)
Resolution 1/4000 (full scale)
Set data 16-bit binary data
Accuracy
(note 3)
23°±2°C
±0.3% of full scale ±0.5% of full scale
(note 3)
0° to
55
°C
±0.5% of full scale ±0.8% of full scale
Com-
Conversion time (note 4) 1.0 ms/point max.
mon
Isolation Between I/O terminals and PC: photocoupler
(No isolation between individual input and
output signals.)
External connectors 28-point terminal block (M3 screws)
Power consumption 100 mA max. at 5 VDC
200 mA max. at 26 VDC
Dimensions 34.5 x 130 x 128 (W x H x D) mm (refer to
Appendix A Dimensions)
Weight 450 g max.
Note 1. The I/O signal range can be set individually for each input.
2. Operate within the ranges listed above. Operation in ranges beyond the
maximum input signals will damage the Unit.
3. The accuracy is given for full scale. For example, an accuracy of ±0.2%
means a maximum error of ±8 (BCD).
The default setting is adjusted with the voltage input for the analog input and
with the current output for the analog output. When using the current input
and voltage output, perform the offset and gain adjustment as required.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC C200H-AD003 and is the answer not in the manual?

Omron SYSMAC C200H-AD003 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC C200H-AD003
CategoryI/O Systems
LanguageEnglish

Related product manuals