Page #11 background imageLoading...
Page #11 background image
- 18 - - 19 -
ORION
Innitely Expandable
3. Guidance for Users
Input/Output Terminals
FAN STB PWR ON
VIDEO
IN OUT
DVI-D
IN OUT
RS-232C
IN OUT
PC
IN OUT
LAN
SVC
ID SELECT
CO., LTD.
Made in Korea
To prevent electric shock, Do not remove cover.
No user serviceable part inside Refer servicing
to qualified service personal.
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION
• Model Name : OLM-4610
• Voltage : AC~100 - 240V
• Current : Max. 3A
• Frequency : 50/60Hz
• Serial No :
MLCD
FAN STB PWR ON
VIDEO
IN OUT
DVI-D
IN OUT
RS-232C
IN OUT
PC
IN OUT
LAN
SVC
ID SELECT
1.PC In / Out
Analog RGB Signal,
D-sub 15pin
2.VIDEO
Composite Signal, BNC Jack
3.DVI
Digital RGB Signal,
DVI Single Link 24Pin
4.RS-232C
MLCD Control, Firmware
Upgrade, D-sub 9pin
5.LAN
Ethernet Control, RJ45
6.Service Port
For the exclusive use of service
7.ID Switch
Set ID Switch
8.AC Input
AC 100V ~240V, 50/60Hz
FAN STB PWR ON
VIDEO
IN OUT
DVI-D
IN OUT
RS-232C
IN OUT
PC
IN OUT
LAN
SVC
ID SELECT
CO., LTD.
Made in Korea
To prevent electric shock, Do not remove cover.
No user serviceable part inside Refer servicing
to qualified service personal.
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION
• Model Name : OLM-4610
• Voltage : AC~100 - 240V
• Current : Max. 3A
• Frequency : 50/60Hz
• Serial No :
MLCD
Set ID Switch Setting
Example of ID Switch setting
- You can set ID with 3 rotary switches as shown in the following figure.
When you set ID of MLCD set, power cable must be disconnected. If power cable is not
disconnected during ID setting, MLCD set may be operated with the previous ID and it may cause
abnormal behavior.
For stable operation, wait for at least 10 seconds prior to use MLCD control program after the first
AC power connection.
The product shape may vary depending on the model.
LED Indication
LED Indication Description
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
FAN STB PWR ON
No Power.
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
FAN STB PWR ON
Insert power cord(Stand-By state)
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
FAN STB PWR ON
Power On By MSCS.
The PWR ON LED blinks continually.
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
FAN STB PWR ON
Power Off by MSCS Program.
(System ready).
FAN : Normal - LED Off, Abnormal - LED On
IF FAN LED is turned on, please check FANs.
ON OFF BLINKING
[MLCD ID 01]
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
[MLCD ID 15]
0
1
2
3
4
5
6
7
8
9
100digit10digitsingledigit
100digit10digitsingledigit
MLCD

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orion OLM-5510 and is the answer not in the manual?

Orion OLM-5510 Specifications

General IconGeneral
BrandOrion
ModelOLM-5510
CategoryMonitor
LanguageEnglish

Related product manuals