- 78 - - 79 -
ORION
Innitely Expandable
- Send to MLCD
A. Normalcommand
STX CMD Length
Data
ETX
ID Master Control
Value 0x02 0x89 0x03 Variable 0x01 Variable 0x03
*IDRange(Program):0x01(1)~0xFF(255)
*Control:0x01(1)~0x06(6)
-1:NoGamma,2:Gamma1.5,3:Gamma1.9,4:Gamma2.0,5:Gamma2.2,6:Gamma2.5
B. Broadcastcommand
STX CMD Length
Data
ETX
ID Control
Value 0x02 0x89 0x02 0X00 Variable 0x03
*MakeallLCDdothesameoperation.But,therewillbenoreturncommunication.(Onewaycommand)
- Receive From MLCD
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 0x89 0x02 Variable 0x01 Variable 0x03
*CheckSum:execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.24. Factory Data (Picture Control Data)
- Command for loading the Picure Control data (User Mode / White Balance / RGB Data / VIDEO Data) adjusted in
the factory.
- It is usable only at Power on Operative
- It shows the value based on current Color Temp. (Normal Mode / Studio Mode.)
- Data can be checked with "Get Picture Control Data" after executing the command
- CMD : 0x82(Save), 0x83(Load)
- Send to MLCD
STX CMD Length
Data
ETX
ID Master
Value 0x02 Variable 0x02 Variable 0x01 0x03
*IDrange(Program):0x01(1)~0xFF(255)
- Receive from MLCD
STX CMD Length
Data
Check Sum ETX
ID Master
Value 0x02 Variable 0x02 Variable 0x01 Variable 0x03
*IDrange(Program):0x01(1)~0xFF(255)
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.
3.25. Get Temperature Status
- Command for acquiring temperature information.
- It is usable only at Power on status.
STX
ETX
02
03
※Attachment : ASCII to HEX Conversion Table
- Send to MLCD
STX CMD Length
Data
ETX
ID Master
Value 0x02 0x7F 0x02 Variable 0x01 0x03
*IDrange(Program):0x01(1)~0xFF(255)
*Itisnotapplicableas"Broad-cast"command.
- Receive from MLCD
STX CMD Length
Data
Check Sum ETX
ID Master
Tempera-
ture Values
Value 0x02 0xF7 0x04 Variable 0x01 Variable 0x03
Temp .0 Tem p.1
Variable Variable
*TemperatureValues(Temp.0,Temp.1)
-0(0x00): 0℃~127(0x7F):127℃
-128(0x80):-1℃~254(0xFE):-127℃
-0xFF:Temp.SensorError
*CheckSum:Execute"Not"operationafteraddingallthevaluesin"STX~Data"area.