44
12. MISC—Miscellaneous
The MISCELLANEOUS screens display extra settings and technical information, some of which is
useful for OutBack Power Systems Technical Services.
The Grid Tie (GT) value is sent
from G-series inverter through the
MATE and HUB for Grid Tie control
communications. GT means The
Charge Controller is in grid tie
mode and communicating with
the GT Series Inverter.
Each MPPT operation is
a state. This number
is useful for OutBack
troubleshooting.
This is the duty cycle of
the converter. At 50%, the
PV terminals would be
twice the battery voltage.
The Bulk/Absorb charge
timer counts up to the
Absorb time limit.
Press NEXT to Continue to the
Force Bulk/Float Screen.
RSTRT forces the Charge
Controller to restart or
wake-up from 5-minute
(default) long Snoozing
mode. Restart and wakeup
are mainly service features.
GT State PWM% ChgT
255 07 50.0 005
EXIT NEXT RSTRT