77
28. STANDARD vs. AUSTRALIAN DEFAULT SETTINGS
The Australian version Charge Controller has a few default settings that di er from the Standard ver-
sion default settings. However, there are no di erences in performance and e ciency between the
two versions. The Standard and Australian version can be identi ed as follows:
Standard Version Australian Version
Below are a few default setting di erences between the Standard and Australian version.
Settings Standard Australian
Charger Absorb Float Absorb Float
12V 4.4V 13.6V 14.4V 13.8V
24V 28.8V 27.2V 28.8V 27.6V
36V 43.2V 40.8V 43.2V 41.4V
48V 57.6V 54.4V 57.6V 55.2V
60V 72.0V 68.0V 72.0V 69.0V
Equalize Equalize Volts Equalize Volts
12V 14.4 14.7
24V 28.8 29.4
36V 43.2 44.1
48V 57.6 58.8
60V 72.0 73.5
Equalize Time 01 Hours 03 Hours