EasyManuals Logo
Home>Outback Power Systems>Controller>FLEXMAX 80

Outback Power Systems FLEXMAX 80 User Manual

Outback Power Systems FLEXMAX 80
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
51
PB
Press the <NEXT> soft key to view the Auto Restart
screen.
Pressing the fourth soft key selects among the three
FLEXmax 80 Auto ReStart modes: 0 (default), 1, and 2.
Auto ReStart allows the FLEXmax 80 to perform internal
recalibrations.
Mode 0Auto ReStart mode is disabled; the FLEXmax
80 recharges continuously from an available source
and never Restarts. Mode 0 would be chosen to avoid
spinning a microhydro generator every 1.5 hours.
Mode 1—once every 1.5 hours, when the FLEXmax 80
is in Bulk, it will briey Restart and initiate a full panel
tracking. This will not reset any counters or charging
stages or statistics.
Mode 2Auto ReStart every 1.5 hours; in Bulk, Absorb,
and Float modes, it will briey Restart and initiate a
full panel tracking. This will not reset any counters or
charging stages or statistics.
ADVANCED MENU
RTS Compensation
A 14.4 V F 13.8V
EXIT NEXT LIMIT SET
AUTO RESTART
ADVANCED MENU
Auto ReStart
MODE 2
EXIT NEXT MODE
ADVANCED MENU
Auto ReStart
MODE 0
EXIT NEXT MODE
ADVANCED MENU
Auto ReStart
MODE 1
EXIT NEXT MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Outback Power Systems FLEXMAX 80 and is the answer not in the manual?

Outback Power Systems FLEXMAX 80 Specifications

General IconGeneral
BrandOutback Power Systems
ModelFLEXMAX 80
CategoryController
LanguageEnglish

Related product manuals