28. STANDARD vs. AUSTRALIAN DEFAULT SETTINGS
The Australian version FLEXmax 80 has a few default settings that dier from the Standard version
default settings. However, there are no dierences in performance and eciency between the two
versions. The Standard and Australian version can be identied as follows:
Standard Version Australian Version
Below are a few default setting dierences between the Standard and Australian version.
Settings Standard Australian
Charger Absorb Float Absorb Float
12V 14.4V 13.6V 14.4V 13.8V
24V 28.8V 27.2V 28.8V 27.6V
36V 43.2V 40.8V 43.2V 41.4V
48V 57.6V 54.4V 57.6V 55.2V
60V 72.0V 68.0V 72.0V 69.0V
Equalize Equalize Volts Equalize Volts
12V 14.4 14.7
24V 28.8 29.4
36V 43.2 44.1
48V 57.6 58.8
60V 72.0 73.5
Equalize Time 01 Hours 03 Hours