2.1.2 Time Service Mode Control
The manager extension or the preprogrammed extension can change the time mode
(Day, Lunch, Break or
Night).
There are two methods (Automatic or Manual) of changing the time modes.
Automatic: enables the time mode for each day of the week to change automatically. You may also change
it manually.
Manual: enables to change a mode manually as follows.
To change the time mode (Day/Night/Lunch/Break)
PT/PS
Press Time Service
(Day/Night/Lunch/Break)
until the desired mode
appears.
(Time Service
(Day/Night/
Lunch/Break))
While on-hook
PT/SLT/PS/SIP Extn.
Off-hook. On-hook.
Enter 780.
1
0
2
3
Day
Night
Lunch
Break
Enter 0 to 3
as you desire.
8 07
C.Tone
To select the time service switching mode (Automatic/Manual)
PT/PS
Press Time Service Switching
Mode (Automatic/Manual).
(Time Service
Switching Mode
(Automatic/Manual))
While on-hook
Besides
the time mode, there is Holiday mode. It can change mode once on a specified date.
The Time Service (Day/Night/Lunch/Break) button light shows the current status as follows:
Off: Day mode
Green on: Lunch mode
Flashing green: Break mode
Red on: Night mode
Flashing red: Holiday mode
The Time Service Switching Mode (Automatic/Manual) button light shows the current status
as follows:
Off: Automatic
Red on: Manual
User Manual 199
2.1.2 Time Service Mode Control

Table of Contents

Other manuals for Panasonic KX-NCP500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-NCP500 and is the answer not in the manual?

Panasonic KX-NCP500 Specifications

General IconGeneral
VoIP SupportYes
Operating SystemProprietary
TypeHybrid IP-PBX
VoIP CodecsG.711, G.729A
ProtocolsSIP, H.323
Operating Temperature0°C to 40°C
Analog ExtensionsYes
IP ExtensionsYes
Power SupplyAC 100-240 V, 50/60 Hz
SIP TrunksYes
Wireless (DECT) ExtensionsYes, with optional module
Weight4.0 kg
Humidity20% to 80% (non-condensing)