EV Charge Control Basic
32 / 68
PHOENIX CONTACT 106377_en_04
Connection of high-power loads (e.g., lamps)
The output stages are supplied with the required voltage of 5 V DC to 30 V DC maxi-
mum via voltage input 12Va.
In status 0 (OFF), the outputs are connected to GND and in status 1 (ON,) they are con-
nected to the potential of 12Va.
GND is connected to PE internally.
Please observe the maximum current capacity of 600 mA per output.
Figure 6-2 Output circuit with lamps
Connection of loads with low current consumption (e.g., LEDs)
The output stages are supplied with the required voltage of 12 V DC from voltage output
12V via voltage input 12Va.
Voltage output 12V can carry a maximum of 500 mA.
In status 0, the outputs are connected to GND and in status 1, they are connected to
12Va.
GND is connected to PE internally.
Figure 6-3 Output circuit with LEDs
Power
L
N
PE
IO
GND
12 V
12 V a
EN
XR
ML
CCR
IN
OUT
ERR
CHG
CON
GND
+5 V DC ... +30 V DC
OUT ERR
CHG CON
Power
L
N
PE
IO
GND
12 V
12 V a
EN
XR
ML
CCR
IN
OUT
ERR
CHG
CON
GND
OUT ERR
CHG CON

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Phoenix Contact EV Charge Control Basic and is the answer not in the manual?

Phoenix Contact EV Charge Control Basic Specifications

General IconGeneral
BrandPhoenix Contact
ModelEV Charge Control Basic
CategoryController
LanguageEnglish

Related product manuals