Connection examples
106377_en_04 PHOENIX CONTACT 39 / 68
7.5 Charging enabled via Modbus
Figure 7-5 Connection example 5
Please observe that the RS-485 cable must be terminated at one point with a 120 Ω
resistor.
S1/DIP 1 = OFF Charging station with Infrastructure Socket Outlet
Value 3 is entered in Modbus register 4000; enable via Modbus register 20000.
Locking is carried out if the vehicle is detected at the charging station and status B is pres-
ent.
The charging process starts if the locking feedback is available and value 1 is written to
Modbus register 20000.