Connections, indicators, configuration switches
106377_en_04 PHOENIX CONTACT 11 / 68
2.2 Diagnostic and status indicators
Figure 2-2 Diagnostic and status indicators
Table 2-2 Diagnostic and status indicators
No. Name Meaning Color Status Description
6 X1 Diagnos-
tics
Reserved for future expansions
PWR Power Green On Charging controller ready
Flashing
(1 Hz)
Charging controller is starting up
CON Connect Yellow On Charging cable is connected to the charging station and the vehicle
Flashing
(1 Hz)
Charging cable is connected to the charging station and locked
ERR Error Red On Error
Flashing
(1 Hz)
Errors that originate at the vehicle or charging cable
CHR Charging Blue On Charging contactor closed
Flashing
(1 Hz)
Vehicle connected, charging current ready, PWM signal switched
on, charging contactor open
L
N
PE
GND
12V
12Va
EN
XR
ML
CCR
IN
OUT
ERR
CHG
CON
C1
C2
A
B
SG
CP
PP
LD1
LD2
L0+
L0-
IO
Relay
R 485S
Outlet
Power
PWR
S1 S2
CON
ERR
CHR
6