10
9850060 R02 - 2020-2021 850 AXYS™ Long Track Snowmobile Service Manual
© Copyright Polaris Inc.
10.15
ADDITIONAL ROUTINGS
EGT SENSOR ROUTING
PIPE EGT SENSOR
1. The EGT sensor
q
is connected into the pipe. Route the EGT sensor wire toward the load center.
2. Take up some slack in the EGT sensor wire harness and secure to the load center bracket with a routing clip
w
.
3. Connect the EGT sensor connector
e
to the main harness connector.