6.3. Lock Settings (Equotip Piccolo 2 only)
The key can be locked to deny access to the instrument settings. When key lock is activated and
the key is pressed,
appears. To lock / unlock settings proceed as follows:
In the Advanced Settings menu, browse to
and confirm with the key .
Use the keys or to choose between lock settings
or unlock settings .
Confirm selection with key . The instrument exits the Advanced Settings menu level and
changes back to the Impact level.
i
Note:
The lock / unlock function can also be controlled using Piccolink.
6.4. Fixed Number of Impacts
(Equotip Piccolo 2 only)
In order to end a testing series, commonly the user closes the series using the key . However, if a
fixed number of impacts, e.g. n = 5, is desired for each series, automatic termination of the series
after 5 recorded values can be set in the Advanced Settings menu level. To set a fixed number of
impacts, proceed as follows:
In the Advanced Settings level, browse to
and confirm with the key .
Use the keys or to decrease or increase (range from 1 to 99) the current number set on the
instrument (e.g.
).
Set the new fixed number of impacts with key . The instrument exits the Advanced Settings
level and changes back to the Impact level.
i
Note:
The number of impacts can also be set using Piccolink.
6.5. Impact Counters (Equotip Piccolo 2 only)
The Equotip Piccolo 2 features two independent impact counters:
The measurement counter can be controlled by the user through Piccolink (see the Piccolink part
of this manual). This counter has its value increased with the first measurement of a series n in
averaging mode, or with each single measurement when the averaging mode is not used.
The impact counter cannot be reset. This counter is increased after each impact.
i
Note:
Whilst the impact counter will mainly be used for reasons of a general overview and
maintenance, the measurement counter may be used by the user to identify a testing
series at the plant. The number of the last completed series is displayed when cycling
through the test statistics.

Table of Contents

Other manuals for Proceq Equotip Piccolo 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Proceq Equotip Piccolo 2 and is the answer not in the manual?

Proceq Equotip Piccolo 2 Specifications

General IconGeneral
BrandProceq
ModelEquotip Piccolo 2
CategoryTest Equipment
LanguageEnglish

Related product manuals