Mail Sets
Adjust the Separation of Special Feeders
Adjust the separation of special feeders as follows:
Push knob A forward until it clicks.1.
2. Turn knob A counter clockwise to open the separation gap.
3. Place a document on the feeder tray and slide it into the system until it can go no
further.
4. Turn knob A clockwise to get resistance.
5. Move the document to and fro. The separation is adjusted correctly when a slight
resistance is felt on the document. Turn knob A counter clockwise again if the
resistance was set too high.