Remote Control
R&S
®
FPC
264User Manual 1178.4130.02 ─ 07
19.12.6 Trigger
TRIGger[:SEQuence]:HOLDoff[:TIME]..............................................................................264
TRIGger[:SEQuence]:LEVel:VIDeo.................................................................................. 264
TRIGger[:SEQuence]:SLOPe.......................................................................................... 264
TRIGger[:SEQuence]:SOURce........................................................................................265
TRIGger[:SEQuence]:HOLDoff[:TIME] <TriggerDelay>
This command defines the length of the trigger delay.
Prerequisites for this command
●
Select external trigger (TRIGger[:SEQuence]:SOURce).
Parameters:
<TriggerDelay> <numeric value>
Range: 0 to 100 s
*RST: 0 s
Default unit: s
Example: //Define a trigger delay
TRIG:SOUR EXT
TRIG:SLOP POS
TRIG:HOLD 500US
Manual operation: See "Trigger" on page 372
See "Trigger" on page 394
TRIGger[:SEQuence]:LEVel:VIDeo <TriggerLevel>
This command defines the level of the video trigger.
Prerequisites for this command
●
Select span = 0 ([SENSe:]FREQuency:SPAN).
●
Select video trigger source (TRIGger[:SEQuence]:SOURce).
Parameters:
<TriggerLevel> <numeric value> (integer)
Range: 0 to 100 %
*RST: 50 %
Example: //Define video trigger condition
FREQ:SPAN 0
TRIG:SOUR VID
TRIG:LEV:VID 50
Manual operation: See "Trigger" on page 372
TRIGger[:SEQuence]:SLOPe <TriggerSlope>
This command selects the slope of the trigger signal.
Remote Commands of the Spectrum Application