Instrument functions
R&S
®
LCX Series
71User Manual 1179.2260.02 ─ 02
8.4 Test signal functions
In this context referred to as test signal parameters, these parameters consider all set-
tings the test signal is composed of. As the core parameters of a measurement, the
R&S LCX provides the access to these settings directly on the screen, and the settings
and function keys.
8.4.1 Test signal settings
With the "Settings" functions, you can define the main characteristics of the test signal.
Access:
1. For accessing the core parameters frequency, level, impedance range and bias,
you have the following options:
Select the softkey of the corresponding parameter on the screen, e.g. "Fre-
quency:".
Press the hardkey of the corresponding parameter at the front panel, e.g.,
[Freq.].
On-screen keypads open providing the corresponding entry fields for setting the
value and the unit of the selected parameter.
2. Enter the value and unit accordingly.
3.
Confirm with
.
The required remote commands are described in:
Chapter 11.4, "Test signal commands", on page 175
Chapter 11.10, "FUNCtion subsystem", on page 194
Chapter 11.5, "BIAS subsystem", on page 178
Frequency: / [Freq.].......................................................................................................71
Level: / [Level]...............................................................................................................71
Range: / [Range]...........................................................................................................72
Current Bias: / [Bias Level]............................................................................................72
Voltage Bias: / [Bias Level]............................................................................................72
[Comp.]..........................................................................................................................72
[Bias Enable].................................................................................................................72
Frequency: / [Freq.]
Sets the test signal frequency.
Remote command:
FREQuency[:CW] on page 177
Level: / [Level]
Sets level of the AC test signal.
To select the parameter for the level setting, see "Test Signal Type" on page 76.
See "About measurement parameters" on page 73.
Test signal functions

Table of Contents

Other manuals for R&S LCX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S LCX Series and is the answer not in the manual?

R&S LCX Series Specifications

General IconGeneral
BrandR&S
ModelLCX Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals