KrosFlo® TFF System Auxiliary Scale ACSS-20K
User Guide
20 repligen.com 420-14871-001 Rev. 00
9.2 ‘Beep’ sound
Parameter allowing to enable/disable sound signal informing the operator about pressing panel
key(s).
1. Enter <P7.Othr / 7.2.bEEP> submenu.
2. Press key, options are displayed successively, where: no sound signal disabled, YES
sound signal enabled.
3. Set respective value and press key to confirm, next go to the home screen.
9.3 Automatic shutdown
Parameter allowing to set time interval, in [min], after which the weighing device shuts down
automatically. If the indication is stable during the declared time interval, the device is shut down.
Shutdown function is inactive, and the device cannot be turned off if any process is started or if you
operate the menu.
1. Enter <P7.Othr / 7.3.t1> submenu.
2. Press key, options are displayed successively, where: nonE Function disabled, 1, 2, 3,
5, 10.
3. Set respective value and press key to confirm, next go to the home screen.
9.4 Date and time
Parameter allowing to set current date and time and to specify date and time format.
Enter <P7.Othr> submenu and change the settings as desired. Refer to the below table:
Table 8. GLP date and time printout variable list
Submenu
Description
<7.4.SdAt>
Enter this parameter to set current date, where the date format is
YYYY.MM.DD*
<7.5.Stnn>
Enter this parameter to set current time, where the time format is 24H**
<7.6.FdAt>
Enter this parameter to set date format. Available values: 1 - DD.MM.YYYY,
2 - MM.DD.YYYY, 3 - YYYY.MM.DD* (set by default), 4 - YYYY.DD.MM
<7.7.Ftin>
Enter this parameter to set time format. Values: 24H** (set by default),
12H**
* Date format: Y year, M month, D day.
** Time format: 12H 12-hour format, 24H 24-hour format.
9.5 Default user settings
Parameter allowing to restore default operator settings.
1. Enter <P7.Othr / 7.8.dFL> submenu, text <Cont?> is displayed (Continue?).
2. Press key to confirm. The process of restoring default settings starts, this is signaled
with display of ‘dash’, <- >.
3. Upon process completion, <7.8.dFLu> submenu is displayed. Return to the home screen.