46 Rockwell Automation Publication 1769-IN088A-EN-P - February 2011
Chapter 2 Module Wiring
1769-OW8I
Compact AC/DC individually isolated, relay contact module
1769-OW16
Compact AC/DC relay contact module
1769-ARM
The 1769-ARM module is an address reserve module for reserving I/O module
slots. As a result, no wiring is required.
L1a or +DCa
L2a or -DCa
OUT 0
OUT 6
OUT 5
OUT 4
OUT 3
OUT 7
VAC-VDC
5
VAC-VDC
4
VAC-VDC
3
VAC-VDC
6
NC
VAC-VDC
7
NC
VAC-VDC
0
CR
L1b or +DCb
L2b or -DCb
OUT 1
VAC-VDC
1
L1c or +DCc
L2c or -DCc
OUT 2
VAC-VDC
2
1769-OW8I
+24V
VAC-VDC
OUT
Simplified Output Circuit Diagram
L1 or +DC
OUT 10
OUT 8
VAC-VDC
2
OUT 6
OUT 4
OUT 11
OUT 9
OUT 3
OUT 1
VAC-VDC
1
L1 or +DC
CR
CR
CR
CR
CR
CR
CR
CR
CR
CR
L2 or -DC
L2 or -DC
OUT 0
OUT 2
OUT 5
OUT 7
OUT 12
OUT 14
OUT 13
OUT 15
1769-OW16
+24V
VAC -VDC
OUT
Simplified Output Circuit Diagram

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley 1769-IA16 and is the answer not in the manual?

Rockwell Automation Allen-Bradley 1769-IA16 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley 1769-IA16
CategoryI/O Systems
LanguageEnglish

Related product manuals