Cookbook Getting Started
15
Note
The software has been installed in the hard disk with the format ".EXT3", so the hard disk is plug and
play.
The hardware disk module does not support hot swapping. You have to reset the device after installing
the hard disk.
Caution
Avoid vibration and collision during device moving and usage.
Products should be transported in original packages.
Errors may occur if a RG-NBR-HDD-1T hard disk is used at an altitude over 3,000 m.
When using the hard disk, do not drop, press on the surface or cover the air hole of the hard disk.
2 Getting Started
2.1 Preparing for Installation
2.1.1 Safety Precautions
The Router acts as the critical transfer station of network connections, and its normal service is crucial to the
normal operation of the entire network. The following safety suggestions are applicable to the installation and
use of the Router:
Do not place the device in a watery place and prevent any liquid from entering into it.
Keep the device away from heat sources.
Wear an ESD wrist strap to install and maintain the device.
Do not wear loose clothes to avoid hooking any parts. Before operation, tighten your band, shawl, and sleeves.
Keep tools and parts away from the walkway to avoid damage.
Use the uninterruptible power supply (UPS) to avoid power failures and other interferences.
2.1.2 Requirements on the Installation Environment
Ruijie RG-NBR-E series Routers are for indoor use only. To ensure normal operation and prolong their service
life, the installation site must meet the following requirements.
1. Temperature/Humidity Requirements
The Ruijie RG-NBR-E series Routers will be damaged when being exposed to an environment that does not
meet temperature/humidity requirements for a long time. To ensure normal operation and prolong the service life
of the router, the equipment room must maintain constant temperature and humidity.
If the relative humidity of the equipment room is above 90%, the insulation materials may result in defective
insulation and even electric leakage.
If the relative humidity of the equipment room is below 10%, the insulation spacer may shrink, which will
make screws looser.
Static electricity may occur in the dry environment, causing damage to the interior circuits of the router.