Troubleshooting
Samsung Electronics 4-5
غ
Vacuum Operation
ـ Operation to facilitate vacuum to open the valve after the Outdoor Unit repair.
غ
Piping Inspection Operation
ـ Operation mode to check the status of the piping between the MCU and the indoor unit.
ـ Heat Pump Model : Outdoor temperature is more than 15°C / Cooling commissioning start
Outdoor temperature is less than 15°C / Heating commissioning start
غ
Discharge Mode Operation
ـ Outdoor power is turned off, the Inverter PCB and Fan PCB charging a high DC voltage, so dangerous to touch.
- To replace the PCB, first turn off the power and the begin if DC voltage is discharged.
- If not use the discharge mode, the discharge time of about 15 minutes takes.
- If an error occurs, the discharge mode may not properly run. (Wait until natural discharge.)
- In particular, E 464, E364, power devices may be damaged, therefore do not use the discharge mode.
ـ Block the Inverter PCB 3-phase relay after connected the power, and through compressor, DC voltage is discharging.
- INV1 and INV2 DC voltage during discharge mode are displayed alternately.
-Discharge mode Display (Rotate the three page display, as shown below.)
 'K' 'A' '' ' ‘ DC Link Volt1 ( For example, 120[V] 0 1 2 0 display)
DCLinkVolt2 ( For example, 120[V] 0 1 2 0 display) 'K' 'A' '' ' ‘ DC Link Volt1 …
ـ Discharge is complete, the power of the Inverter PCB and Fan PCB is being blocked, communication function is blocked, E206 will
occur.
ـ If want operation again after complete discharge mode : Restart after K3 key to Reset or Power Reset.
How to Initiate K1 Tact Switch 7 times~11 times
Compressor OFF
Indoor Unit/Outdoor Fan OFF
4Way Valve OFF
Valves Open all valves maximum
Etc. If not turn off the vacuum mode, the start of normal operation is pr ohibited.

Table of Contents

Other manuals for Samsung AM250FNBFEB/EU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Samsung AM250FNBFEB/EU and is the answer not in the manual?

Samsung AM250FNBFEB/EU Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Gas hose diameter15.88 mm
Liquid hose diameter9.52 mm
Refrigerating mediumR410A
Air conditioner functionsHeating
Heating capacity (nominal)85300 BTU/h
Heating capacity in watts (max)25000 W
Cooling capacity in watts (nominal)- W
Operating temperature (heating) (T-T)-20 - 24 °C
AC input voltage220-240 V
Current (heating)23.1 A
AC input frequency50-60 Hz
Design load (cooling)- kW
Energy efficiency scaleA+ to G
Power consumption (heating) (max)5000 W
Hourly energy consumption (cooling)- kWh
Energy efficiency class (heating) (Average heating season)A+
Indoor unit typeWall-mountable
Indoor unit depth330 mm
Indoor unit width518 mm
Indoor unit height1210 mm
Indoor unit weight104000 g
Indoor units quantity1
Indoor unit package depth426 mm
Indoor unit package width652 mm
Indoor unit package height1289 mm
Indoor unit package weight107000 g
Indoor unit sound power level42 dB
Indoor unit noise level (high speed)61 dB
Outdoor unit noise level- dB