- 89 -
Electrical Adjustments
9. Common center adjustment
Equipment Oscilloscope
Input mode Computer mode
Input signal 50% (R,G,B) pattern signal
1. Enter the service mode.
2. Project only one color component to the screen.
Select Group "900", No. "1" and then change data value
from "2" to "0".
3. Change data value to obtain the minimum flicker for
each color on screen.
Group No. Screen
280 - 9 Only green color picture
280 - 10 Only blue color picture
280 - 11 Only red color picture
4. Select Group "900", No. "1" and then change data value
from "0" to "2".
10. Gamma correction, White balance, White
uniformity Adjustment
If the correction of the Gamma adjustment, White balance
adjustment, White uniformity adjustment is necessary,
please adjust the "Gamma", "White balance", "White uni-
formity" by using the "PROJECTOR SERVICE TOOL" soft-
ware supplied separately.
Check and adjustment : 4 Lamp mode
Lamp 1-4 mode
Lamp 2-3 mode
11. Read/Write of LCD panel gamma data
when Main Board replacing
The gamma adjustment data of each LCD panel has been
adjusted preciously to much each LCD panel characteristics
at factory.
When you replace the Main Board, you need to read out
the gamma data stored in the memory IC on the previous
board and write down the gamma data into the memory
IC on the new board. By this way, the projector is enabled
to reproduce the picture which has the properly adjusted
gamma characteristic.
Use "PROJECTOR SERVICE TOOL" for Read / Write of the
gamma data as follows;
PROJECTOR SERVICE TOOL Ver. 4.10
Service Parts No. 610 337 8787
12. Color Shading Correction
If you find the color shading on the screen, please adjust
the white uniformity by using the proper computer and "
PROJECTOR SERVICE TOOL" software supplied separately.
The software can be orderd as follows;

Other manuals for Sanyo PLC-XF47

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XF47 and is the answer not in the manual?

Sanyo PLC-XF47 Specifications

General IconGeneral
Vertical scan range48 - 120 Hz
Horizontal scan range15 - 120 kHz
Projection technologyLCD
Contrast ratio (typical)2000:1
Screen size compatibility40 - 600 \
Projector native resolutionXGA (1024x768)
Keystone correction, vertical80 °
Keystone correction, horizontal40 °
I/O portsAnalog (D-sub15), Serial in & Serial out (D-Sub 9 x 2)
Video outUXGA, SXGA+, SXGA, WXGA, XGA, SVGA, VGA, MAC
Resolution2359296 pixels
Aspect ratio4:3
RS-232 ports1
Dimensions (WxDxH)581 x 815.5 x 251.5 mm
Power requirements200-240 V AC 9.7 A Max, 50 / 60 Hz
Connectivity technologyWired
Lamp typeNSH
Lamp power330 W
Light source typeLamp
Dot clock scanning frequency230 MHz
Serial interface typeRS-232
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Power consumption (typical)1700 W
Weight and Dimensions IconWeight and Dimensions
Weight36500 g

Related product manuals