Lamp Replacement
How to check Lamp Used Time
The LAMP REPLACE indicator will light yellow when
the total lamp used time (Corresponding value) reaches
3,000 hours. This is to indicate that lamp replacement is
required.
The total lamp used time is calculated by using the be-
low expression,
Total lamp used time = Teco + Thigh/normal x 1.5
Teco: used time in the Eco mode
Thigh/normal : used time in the Normal mode and
High mode.
You can check the lamp used time following to the below
procedure.
1 Press and hold the ON/STAND-BY button on the pro-
jector for more than 20 seconds.
2 The projector used time and lamp used time will be
displayed on the screen briefly as follows.
Recommendation
Should the air filter become clogged with dust particles, it will reduce the cooling fan’s effectiveness and may result in
internal heat build up and short lamp life. We recommend cleaning the air filter after the projection lamp is replaced.
Refer to “Air Filter Cleaning”.
Counter
Projector 500H
Lamp
High/Normal 200 H
Eco 300 H
Corresponding value 600 H
Total lamp used time
Projector used time
Resetting the Lamp Counter
Be sure to reset the Lamp replacement counter after the
lamp is replaced.
Press the Point
▲▼
buttons to choose the Lamp counter
function and then press the Point
or the SELECT button to
access the submenu items.
Lamp counter................This item shows the total
accumulated time of the lamp
usage.
Lamp counter reset.......Press the the SELECT button
to choose Lamp counter reset.
Select Yes in the confirmation
box if you want to reset the lamp
counter, and then choose Yes in
the second confirmation box to
reset lamp counter.