Lamp Replacement
Lamp replacement
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
 
WARNING : TURN OFF THE UV LAMP BEFORE OPENING THE LAMP COVER.
USE UV RADIATION EYE AND SKIN PROTECTION DURING SERVICING.
For continued safety, replace with a lamp of the same
type. Do not drop a lamp or touch a glass bulb! The
glass can shatter and may cause injury.
Allow a projector to cool for at least 45 minutes
before you open the Lamp Cover. The inside of the
projector can become very hot.
CAUTION
CAUTION
CAUTION
When replacing the lamp because it has stopped illuminating, there is a possibility that the lamp may be
broken.
If replacing the lamp of a projector which has been installed on the ceiling, you should always assume that the
lamp is broken, and you should stand to the side of the lamp cover, not underneath it. Remove the lamp cover
gently. Small pieces of glass may fall out when the lamp cover is opened. If pieces of glass get into your eyes
or mouth, seek medical advice immediately.
ORDER REPLACEMENT LAMP
Type No. POA-LMP132
Service Parts No. 610 345 2456
Follow these steps to replace the lamp.
Unplug the AC power cord. Let the projector cool for at
least 45 minutes.
Loosen the three (3) screws that secure the lamp. Lift
the lamp out of the projector by using the handles.
1
3
Replace the lamp with a new one and secure the three
(3) screws. Make sure that the lamp is set properly.
Close the lamp cover and secure the screw.
4
Loosen the screw and open the lamp cover.
2
Connect the AC power cord to the projector and turn
on the projector.
5
Reset the Lamp Replace Counter.
Refer to the next page for details.
6
Lamp
Screw
Handles
Screw
Lamp Cover
Screw
Screw

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo PLC-XR201 and is the answer not in the manual?

Sanyo PLC-XR201 Specifications

General IconGeneral
BrandSanyo
ModelPLC-XR201
CategoryProjector
LanguageEnglish

Related product manuals