Technical specifications
7.4 Technical data
SIMATIC IPC227E
102 Operating Instructions, 11/2016, A5E35782395-AB
Ambient conditions
Climatic ambient conditions
The temperature values have been checked in accordance with IEC 60068-2-1,
IEC 60068-2-2 and IEC 60068-2-14. For permitted mounting positions, see section
"Preparing installation".
Note
Installation at temperatures > 50 °C in RAL only
If you wish to install the device at an ambient temperature of >
+50 °C, you will have have to
install it in a Restricted Access Location (RAL) such as a lockable control cabinet.
All device versions with HDD
+5 … +40 °C, horizontal and vertical installation
Operation, USB load max. 6 W:
• Basic device
• PCIe device version, load max. 5 W
0 … +50 °C applies to device with:
• CFast card, SSD
• horizontal and vertical installation
Operation, USB load max. 6 W:
• Basic device
• PCIe device version, load max. 3 W
0 … +60 °C applies to device with:
• CFast memory card
• horizontal installation only
Gradient
• Operation: Max. 10 °C/h
• Storage: 20 °C/h, no condensation
Relative humidity
• Operation
• Storage/transport
Tested in accordance with IEC 60068-2-78,
IEC 60068-2-30
5 … 85 % at 30 °C, no condensation
5 … 95 % at 25/55 °C, no condensation
Barometric pressure
• Operation
• Storage/transport
1080 to 795 hPa, corresponds to an elevation of -
1000 to 2000 m
1080 to 660 hPa, corresponds to an elevation of -