Technical specifications
7.5 Hardware descriptions
SIMATIC IPC227E
116 Operating Instructions, 11/2016, A5E35782395-AB
Input/output address areas
7.5.5.1
Overview of the internal module registers
The following addresses are used for the internal registers:
Watchdog enable register / 066h select register (Page 116)
Watchdog trigger register (read only, address 066h) (Page 117)
Output register LED 1/2/3 and SF LED / RUN/STOP LED (Page 117)
I/O 404Dh Battery status register (read-only) (Page 118)
Watchdog enable register / 066h select register (read/write, address 062h)
Meaning of the bits
Watchdog enable register / 066h select register (r/w address 062h)
Watchdog enable bit (WDE)
Watchdog circuit disabled
066h select register selection
Scaler watchdog time (Normal/Macro)
1 1 0 840 ms / 48 s