Technical specifications
7.5 Hardware descriptions
SIMATIC IPC227E
116 Operating Instructions, 11/2016, A5E35782395-AB
7.5.5
Input/output address areas
7.5.5.1
Overview of the internal module registers
The following addresses are used for the internal registers:
Addresses
Input/output unit
I/O 062h
Watchdog enable register / 066h select register (Page 116)
I/O 066h
Watchdog trigger register (read only, address 066h) (Page 117)
I/O 404Eh - 404Fh
Output register LED 1/2/3 and SF LED / RUN/STOP LED (Page 117)
I/O 404Dh Battery status register (read-only) (Page 118)
7.5.5.2
Watchdog enable register / 066h select register (read/write, address 062h)
Meaning of the bits
Watchdog enable register / 066h select register (r/w address 062h)
Bit
Meaning of the bits
7
6
5
4
3
2
1
0
Watchdog enable bit (WDE)
0
Watchdog circuit disabled
1
Watchdog circuit enabled
Watchdog Mode
0
Standard
1
Macro
066h select register selection
0
Reserved
1
Scaler watchdog time (Normal/Macro)
0
0
0
94 ms / 2 s (default)
0
0
1
210 ms / 4 s
0
1
0
340 ms / 6 s
0
1
1
460 ms / 8 s
1
0
0
590 ms / 16 s
1
0
1
710 ms / 32 s
1 1 0 840 ms / 48 s
1
1
1
960 ms / 64 s

Table of Contents

Other manuals for Siemens simatic ipc227e

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simatic ipc227e and is the answer not in the manual?

Siemens simatic ipc227e Specifications

General IconGeneral
BrandSiemens
Modelsimatic ipc227e
CategoryIndustrial PC
LanguageEnglish

Related product manuals