Mounting and connecting the device
3.3 Connecting the device
SIMATIC IPC677D
Operating Instructions, 09/2014, A5E32995420-AC
41
Procedure
1.
Make s
ure that the ON/OFF switch is in position '-'
(Off) to avoid unintentional startup of the device
when you plug in the power cord.
2.
Connect the appliance connector to the device.
3.
Connect the power cable with the safety power
outlet.
4.
If necessary, install the enclosed cable grip.
3.3.4
Connecting the 24 VDC power supply
Note before connecting the device
WARNING
Safety extra-low voltage (SELV)
The device should only be connected to a 24 V DC power supply which meets the
requirements of safe extra low voltage (SELV) according to IEC/EN/DIN EN 60950-1. A
protective conductor must also be used. The conductors must withstand the short-circuit
current of the 24 V DC power source, so that a short-circuit will not damage the cable. Only
connect cables with a minimum cross-section of 1.3 mm
2
(AWG16) and a maximum cross-
section of 3.3 mm
2
(AWG12).
Note
The 24 V DC power source must be adapted to the input data of the device (see
specifications).

Table of Contents

Other manuals for Siemens SIMATIC IPC677D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC677D and is the answer not in the manual?

Siemens SIMATIC IPC677D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC677D
CategoryIndustrial PC
LanguageEnglish

Related product manuals