Description of the motors
2.3 Technical features and environmental conditions
S-1FT7 synchronous motors
24 Configuration Manual, 09/2018, A5E45099423B AA
2.3
Technical features and environmental conditions
2.3.1
Standards and guidelines
Standards that are complied with
The motors of the type series SIMOTICS S, SIMOTICS M, SIMOTICS L, SIMOTICS T,
SIMOTICS A, called "SIMOTICS motor series" below, fulfill the requirements of the following
directives and standards:
EN 60034-1 - Rotating electrical machines Dimensioning and operating behavior
EN 60204-1 - Safety of machineryElectrical equipment of machines; general
requirements
Where applicable, the SIMOTICS motor series are in conformance with the following parts of
IEC / EN 60034:
Feature
Standard
Degree of protection
IEC / EN 60034-5
Cooling
1)
IEC / EN 60034-6
Type of construction
IEC / EN 60034-7
Connection designations
IEC / EN 60034-8
Noise levels
1)
IEC / EN 60034-9
Temperature monitoring
IEC / EN 60034-11
Vibration severity grades
1)
IEC / EN 60034-14
1)
Standard component, e.g. cannot be applied to built-in motors
Relevant directives
The following directives are relevant for SIMOTICS motors.
European Low-Voltage Directive
SIMOTICS motors comply with the Low-Voltage Directive 2014/35/EU.
European Machinery Directive
SIMOTICS motors do not fall within the scope covered by the Machinery Directive.
However, the use of the products in a typical machine application has been fully assessed
for compliance with the main regulations in this directive concerning health and safety.
European EMC Directive
SIMOTICS motors do not fall within the scope covered by the EMC Directive. The products
are not considered as devices in the sense of the directive. Installed and operated with a
converter, the motor - together with the Power Drive System - must comply with the
requirements laid down in the applicable EMC Directive.