EasyManuals Logo
Home>Siemens>Engine>SIMOTICS XP 1MB1 series

Siemens SIMOTICS XP 1MB1 series User Manual

Siemens SIMOTICS XP 1MB1 series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #134 background imageLoading...
Page #134 background image
Maintenance
9.3 Corrective maintenance
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
132 Operating Instructions, 06/2018, A5E44455710A
Use a suitable tool to pull off the fan (puller).
Locate the arms of the pulling tool in the breakout openings and slightly tension the
pressure screw of the tool.
For fans with snapping mechanisms, simultaneously release the two snap-in lugs of the
fan from the annular shaft groove.
Keep the snap-in lugs in this position.
Uniformly withdraw the fan from the shaft by turning the pressure screw of the pulling tool.
Do not apply any hammer blows to avoid damaging the rotor shaft, the fan and the
bearings.
Order the appropriate new parts if damaged.
9.3.6.1
Metal fan disassembly
Metal fan
Remove the locking ring.
Use a suitable tool to pull off the fan (puller).
Locate the arms of the pulling tool in the openings in the fan in the vicinity of the hub.
Alternatively, place the pulling tool at the outer edge of the fan plate.
Uniformly withdraw the fan from the shaft by turning the pressure screw of the pulling tool.
Do not apply any hammer blows to avoid damaging the rotor shaft, the fan and the
bearings.
Order the appropriate new parts if damaged.
9.3.6.2
Mounting fans
Take care not to damage the snapping mechanisms on fans that are equipped with these.
To ensure this, the fans should be heated to a temperature of approximately 50 °C
around the area of the hub.
If any damage is caused, request new parts.
9.3.7
Cable entries, sealing plugs and thread adapters
All cable entries and sealing plugs must be approved for use in the respective hazardous
zone.
Any openings that are not being used must be sealed using the appropriate certified
sealing plugs.
Please observe the manufacturer's specifications when fitting cable entries.
Note the following when mounting:
Avoid damaging the cable jacket.
Adapt the tightening torques to the cable jacket materials.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP 1MB1 series and is the answer not in the manual?

Siemens SIMOTICS XP 1MB1 series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP 1MB1 series
CategoryEngine
LanguageEnglish

Related product manuals