Figure 5-9 Activating load to file system know-how protection
The active input fields are mandatory inputs.
3. Enter the required password in the "New password" field and enter it again in the "Confirm
password" field.
4. If the associated input fields are active, enter the serial numbers:
The serial number of the new memory card for which the data is intended
The serial number of the Control Unit
5. If, despite active know-how protection, you permit diagnostic functions, activate the "Allow
diagnostic functions (trace and measuring function)" option with a mouse click.
This allows the trace function, the measuring function and the function generator to be used
despite know-how protection.
6. Click "OK" to confirm the settings you made.
Result
The activation of the know-how protection starts the encryption of the subproject data. If larger
data volumes are being encrypted, a progress display informs that the encryption or the
activation of the know-how protection is still running. With the aid of this encrypted data, an
end user can install a new memory card for the drive unit.
5.2.3 Overview of important parameters
Overview of important parameters
Note
For a description of the parameters, see the converter List Manual.
Security measures for SINAMICS
5.2 Write protection and know-how protection
Industrial Security
Configuration Manual, 08/2017, A5E36912609A 47

Table of Contents

Other manuals for Siemens SINAMICS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS and is the answer not in the manual?

Siemens SINAMICS Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS
CategoryDC Drives
LanguageEnglish

Related product manuals