The following conditions must be ensured to make
this check:
– key set to «ON»,
– connector CN2 connected,
– operator seated,
– blades disengaged.
The check is made with the tester in Voltmeter mo de
(0 ÷ 20 Volts DC) and with the probes on the connec-
tor (2) output cabling terminals.
When one of the two keys is pressed the instrument
reading shows the battery voltage (positive or nega-
tive); this value must never fall below 11.5 Volts.
If no power is detected it means that the 15 A fuse has
blown or that there is a fault in the actuator board.