50 034, 036, 036 QS
10.1.2 Test Connections and Test Values
– The pin and socket connections
of wires 1 to 4 must be
disconnected to test the
individual components.
(see 10.1, fig.138 RA 132 VA)
Component Ohmmeter connection
(use either test lead)
Resistance If faulty
Leadl 1 Lead 2 Spec. Actual Cause Remedy
Switch Switch
terminal
Ground 0 - Switch faulty Replace switch
Heating element, rear
handle (previous)
Connector
on wire 3
Connector
on wire 4
0.25 approx.
0.25
Heating element OK
- Break in wire, heating
element damaged
Replace heating
element
0 Short circuit -
damaged insulation
Repair
insulation
Heating element, rear
handle (new version)
Connector
on wire 3
Connector
on wire 4
1 approx.
1
Heating element OK
- Break in wire,
Heating element
damaged
Replace heating
element
0 Short circuit -
damaged insulation
Repair
insulation
Heating element, front
handle (previous)
Connector
on wire 2
Ground 1.6 approx.
1.6
Heating element OK
- Break in wire, heating
element damaged
Replace front
handle
0 Short circuit durch
damaged insulation
Repair
insulation
Heating element in
front handle (new
version)
Stecker an
Leitung 2
Ground 7 approx.
7
Heating element OK
- Break in wire,
Heating element
damaged
Replace front
handle
0 Short circuit -
damaged insulation
Repair
insulation
Generator Connector
on wire 1
Ground 0.6 approx.
0.6
Generator OK
- Break in wire,
generator damaged
Replace
generator
0 Short circuit -
damaged insulation
Repair
insulation