ELECTRICAL 4-3
INSPECTION
BATTERY CHARGE COIL
Measure battery charge coil resistance.
\ 09930-99320 : Digital tester
V Tester range :
ΩΩ
ΩΩ
Ω (Resistance)
1. Disconnect battery charge coil leads from rectifier & regu-
lator.
2. Measure resistance between leads in the combinations
shown.
Battery charge coil resistance :
If out of specification, replace battery charge coil.
FUSE CASE / FUSE
\ 09930-99320 : Digital tester
T Tester range :
@@
@@
@ (Continuity)
Fuse
1. Remove fuse from fuse case (or fuse terminal).
2. Inspect continuity between both terminals of fuse.
If no continuity is exists, replace fuse.
Main fuse : 60A
Sub fuse : 30A
Main fuse terminal
Inspect continuity between terminal (A) and (B).
If no continuity is exists, replace fuse terminal and/or fuse.
Terminal for tester probe
connection
Resistance
White
1 to White 2
White 2 to White 3
White 3 to White 1
0.16 – 0.24 Ω
Main fuse
Sub fuse
A
B
1
2
1. Main fuse
2. Sub fuse
1. Main fuse
2. Sub fuse
A
B
1
2
W
3
W
2
W
1