11
INSTALLATION & WORK STATION
To obtain the 2 Year Plus Warranty, an authorized or cered espresso service representa-
ve must perform the installaon of this espresso machine.
Site Preparaon - See Diagram on page 12
The machine must be placed on a level horizontal surface that can be easily cleaned and is capable of sus-
taining a minimum of 300 lbs.
The counter top requires a depth of 28”, which provides a minimum clearance of 1” behind and 3” in front
of the machine.
Make a 2 ½” minimum diameter hole through the counter top located 4” from the rear and 7” from the right
side of the machine. The hoses, drain tube, and electrical lines will all pass through this hole.
A 3/8” min. diameter cold water supply line from the lter with a shut o valve is required within 5’ of the
machine. The valve should be easily accessed for machine service.
The machine supply hose and pump ngs are 3/8” tube compression ngs.
A proper water ltraon or soening system must be installed on the incoming water supply. Water treat-
ment requirements will vary and it is important to use a system designed to match the needs of your specic
area. Water ltraon systems require periodic maintenance, including cartridge or lter replacement. Prop-
er ltraon and service is vital to the funcon of the machine and the quality of the espresso served. Follow
the instrucons provided by your water treatment system for proper installaon.
Note: Improper water ltraon can result in severe damage to the machine including scale deposits and cor-
rosion. DAMAGE CAUSED BY IMPROPER WATER TREATMENT WILL NOT BE COVERED BY THE MACHINE
WARRANTY. See page 8.
There must be adequate room under the counter to locate each motor and pump. The pumps must be easily
accessible for adjustment and motors must have a minimum of 3” clearance on all sides for air ow.
A oor drain or sink must be available. The best locaon is directly under the machine. The 3/4” drain hose
should descend as vercally as possible for opmal drainage. An air gap is required between the end of the
drain hose and the highest water posion of a clogged drain. This is to prevent the possibility of drain water
backing up into the machine.