START UP
Start-Up Instrucons
1. Connect the water lines and the drain hose. Turn the water ON. Water will begin to ow into the brew
groups.
2. Ensure the heang element breaker switch is in the OFF posion. Then switch the red electronics On/O
switch to the ON posion. The machine’s auto-ll feature will acvate and the steam tank will begin lling.
3. The water level sight glass for the steam tank is located on the right side of the machine. As the tank lls,
the water level will rise in the sight glass and will automacally stop when the correct level is reached.
4. Bleed the group heads of air:
• Hold each brew group handle le unl the corresponding display reads M: shi each group head handle
le momentarily, (see pictures below) allow the group to run unl there is a steady ow of water. Shi
each group head right to turn o.
5.Wait unl the steam tank has stopped lling and the level in the sight glass reads at least ½ full. Turn the
heang element breaker to the ON or (1) posion. All the heang elements (brew and steam) are now ac-
vated.
Electronics Switch
ON: up posion, light
on
OFF: down posion,
light o
Heang Element Switch
ON: le posion (1)
OFF: right posion (0)
1 0
Machine Switches
Center Posion—At Rest Shi Le - Start or Advance
Hold Le - Changes M to MP to VP
Shi Right - O or Select Brew