In an eort to prevent damage to machines and to help operators troubleshoot issues, Synesso has engi-
neered several safeguards into the programming. By understanding these codes, operators can remedy is-
sues more quickly. The most recent error can be found on the temperature overview screen at the lower
right corner.
Error code key (See Pages 44-50 for more info)
BR - Brew System
Codes
GROUP
1
GROUP
2
GROUP
3 CODE DESCRIPTION
BV - Brew valve BRBV01 BRBV02 BRBV03 Brew Valve has been on for 5 consecuve minutes
OT - Over Temp BROT01 BROT02 BROT03 Over Temperature (220°F)
UT - Under Temp BRUT01 BRUT02 BRUT03 Group reads < 180°F for 1 minute while reheang
BP - Bypass Valve BRBP01 BRBP02 BRBP03 Bypass Valve has been held on for 5 consecuve minutes
ST - Steam System Codes
LOW H2O Low level probe not in contact with water (audible alarm)
LW - Low Water Probe STLW00 N/A N/A Indicates past LOW H2O warning
FP - Fill Probe STFP00 N/A N/A Fill Probe is not in contact with water for 1 minute
FV - Fill Valve STFV00 N/A N/A Fill Valve has been on for 5 consecuve minutes.
OT - Over Temp STOT00 N/A N/A Over Temperature (270°F)
VM - Volumetric System Codes
UF - Unexpected Flow VMUF01 VMUF02 VMUF03 Unexpected ow detected while group is o
Menu Level 1: Brew System Error Codes