FLOWMETER CALIBRATION INSTRUCTIONS
These instrucons are to be performed using the owmeter calibraon feature made available with rmware
version 2.64. See page 54 for informaon on accessing this feature in the programming.
WARNING: It is recommended that this calibraon be performed while the machine is cool and the heang
elements are o. Performing the calibraon while the machine is hot can lead to errors in desired accuracy.
Materials Needed:
Cup (or pitcher, etc.) with at least 250ml capacity and a wide enough mouth to capture water
dispensed from brew group
Sloed screwdriver short enough to t under group head (might need stubbyone)
Graduated cylinder with 250ml capacity and 2ml resoluon or beer.
WARNING: Some users may prefer to use a scale instead of a graduated cylinder. Note that the density of wa-
ter varies as a funcon of temperature. Grams and milliliters are equivalent for water at 4°C (just above freez-
ing.) However, at brew temperatures water density is closer to 0.97g / ml. Therefore, if you weigh some wa-
ter (in grams) out of a hot brew group and want to calculate its volume (in ml,) you must divide by roughly
0.97.
Calibraon Instrucons:
1. Clean and backush the brew groups.
2. Remove the diuser screens and screws.
3. Ensure the heang element breaker is o.
4. In order to make the starng brew pressures more consistent, run each group briey without the
pump on. This can be done using the BREW VALVES funcon on the TEMPERATURE DISPLAY
screen found in the 2nd level menu (see page 52).
5. In the 2nd level menu, cycle to the FLOWMETER CALIBRATION screen. (see page 54)
6. Posion the cup under the 1st brew group
7. Follow the on screen prompts to dispense a test volume of water into the cup. The machine will automa-
cally stop when the test volume of water has been dispensed (approximately 250 ml).
8. Carefully transfer the water from the cup into the graduated cylinder and measure the volume.
9. Enter the measured volume on the screen.
10. Proceed to the next brew group, repeang steps 6-9 unl all groups are calibrated.
11. Return to the TEMPERATURE OVERVIEW home screen.
Oponal Vericaon:
Note: the vericaon step does not ulize the calibraon program, but is intended to verify that the calibra-
on was successful.
1. In the rst level menu, adjust the volume for program 1 on each group up to 444 TOTAL WATER COUNT.
2. Run program 1 on all of the brew groups for a few seconds to get each group up to pump pressure.
3. Posion the cup under the 1st brew group.
4. Run program 1 to dispense 444 cks worth of water into the cup.
5. Verify with the graduated cylinder that the group has dispensed 100ml of water.
6. Proceed to the next brew group, repeang steps 3-6 unl all of the groups are veried.
7. Turn the heang elements back on and reinstall the diuser screens and screws.

Table of Contents

Other manuals for Synesso MVP Hydra

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Synesso MVP Hydra and is the answer not in the manual?

Synesso MVP Hydra Specifications

General IconGeneral
BrandSynesso
ModelMVP Hydra
CategoryCoffee Maker
LanguageEnglish

Related product manuals