EasyManuals Logo
Home>TECO>Servo Drives>JSDAP Series

TECO JSDAP Series User Manual

TECO JSDAP Series
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
5-40
5-4-4 Smooth Acceleration
Using the One Time Smooth Acceleration/Deceleration of Position Command
It smoothes the position pulse command frequency.
Parameter
Signal
Name Default Unit Setting Range Control Mode
Pn313
External Position
command
Accel/Decel Time
Constant
0 msec 0~10000 Pi/Pe
New setting will become effective after re-cycling the power.
Time Constant of Smooth Acceleration/Deceleration of Position Command defined for a cycle as below:
The require time of the Position Pulse Frequency started from 0 to 63.2%.
Frequency of Position
Pulse Command (%)
Time (ms)
Pn313
100
50
63.2
Frequency of Position Pulse Command
Setting Examples:
(1) To achieve 95% of Position Pulse Command Frequency Output in 30msec:
10(msec)
95%)-ln(1-
30(msec)
Pn313
(2) To achieve 75% of Position Pulse Command Frequency Output in 30msec:
22(msec)=
75%)-ln(1-
30(msec)
=Pn313
Note: Above curve is a logarithmic
ln = Natural log.

Table of Contents

Other manuals for TECO JSDAP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TECO JSDAP Series and is the answer not in the manual?

TECO JSDAP Series Specifications

General IconGeneral
BrandTECO
ModelJSDAP Series
CategoryServo Drives
LanguageEnglish

Related product manuals