EasyManuals Logo
Home>TECO>Servo Drives>JSDAP Series

TECO JSDAP Series User Manual

TECO JSDAP Series
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #162 background imageLoading...
Page #162 background image
5-76
Analog monitor output zero offset can be adjusted by parameters Cn027&Cn028 as below.
Parameter Name Default Unit Setting Range Control Mode
Cn027
Analog Monitor 1
Offset adjustment
4 x40mV -250~250 ALL
Cn028
Analog Monitor 2
Offset adjustment
4 x40mV -250~250 ALL
Analog Monitor
Output Voltage (V)
Adjusting Value for
Bias Voltage
Time
5-6-12 Factory Setting Parameter
This parameter can reset all parameter settings to default value (factory reset).
Parameter Name Setting Description
Control
Mode
0 Disabled
Cn029
Reset parameters
1 All parameters are reset to default values.
ALL
New setting will become effective after re-cycling the power.