Three indicators, displayed on the crt and labeled on
the bezel tag, display the condition of the options. A bat
tery backed-up CMOS memory and its battery are also
included in the options. Option commands allow saving
additional SAVE REF waveforms in the memory.
Options—2230 Service
WARNING
The battery used in this device contains lithium. Do
not expose to heat Do not short terminals. See ser
vice information for complete instructions.
The communication options allow remote control of
oscilloscope functions. This remote control is accom
plished by messages sent to the instrument via either the
GPIB (IEEE-488 Standard Bus) or the RS-232-C interface.
Messages used are defined either in ANSI/IEEE-488-1978
or in the Tektronix standard on Codes, Formats, Conven
tions, and Features. Messages to the option can have one
of three purposes:
1. Query the state of the oscilloscope.
2. Query the results of measurements made.
Set the instrument operation mode.
The main purpose of the communication options is to i
allow digitized waveform data to be sent and received by
the instrument.
STANDARD FUNCTIONS,
FORMATS, AND FEATURES
The interface-function repertoire of a GPIB instrument,
in terms of interface-function subsets, is identified in
ANSl/IEEE Std 488-1978. The status of subsets applicable
to this instrument with Option 10 are listed in Table 7-1.
Both the GPIB interface and the RS-232-C interface
conform to a Tektronix standard on Codes, Formats, Con
ventions, and Features of messages sent over the bus to
communicate with other instruments equipped with a like
interface. Specific features implemented in this instrument
are listed in Table 7-2, and specific formats implemented
are shown in Table 7-3.
Table 7-1
Function Subsets Implemented
Function Subset Capability States Omitted
Other Requirements
Other Subsets
Required
SHI (Source Handshake) Complete Capability None
None
T6
AH1 (Acceptor
Handshake)
Complete Capability None
None
None
T6 (Talker) Basic Talker, Serial Poll,
Talker Only, Unaddress if
MLA
None
Include [MLA (ACDS)]
SHI and L3
L3 (Listener)
Basic Listener, Listen
Only, Unaddress if MTA
None
Include [MTA (ACDS)]
AH1 and T6
SRI (Service Request) Complete Capability None
None
T6
RL2 (Remote/Local)
No Local Lock Out
LWLS and
RWLS
None
L3
PPO (Parallel Poll)
No Capability
All
None
None
DC1 (Device Clear) Complete Capability
(Selective Device Clear)
None
None
L3
DTO (Device Trigger)
No Capability
All
None
None
CO (Controller)
No Capability All
None
None
E2 (Drivers)
Three-state
7-2

Table of Contents

Other manuals for Tektronix 2230

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2230 and is the answer not in the manual?

Tektronix 2230 Specifications

General IconGeneral
BrandTektronix
Model2230
CategoryTest Equipment
LanguageEnglish

Related product manuals