Specification—2465B/2467B Service
Table 1-2
Option 06 (C/T/T) Electrical Characteristics
Characteristics Performance Requirements
SIGNAL INPUT
Maximum Input Frequency for Count and
Events
Delay by
Minimum Width of High or Low State of Input Signal
for Count and Delay by Events
Sensitivity
Dc to 50 MHz (0.5 Hz to 50 MHz for
Frequency and Period)
CH 1 and CH 2
CH 3 and CH 4
50 MHz to 150 MHz
CH 1 and CH 2
CH 3 and CH 4
With DC Coupling of A Trigger and B Trigger.
3*150
MHz.
*s3.3 ns.
For Count, Delay by Events, and Logic Trigger Functions
Excluding Word Recognizer.
1.5 divisions.
0.75 division.
4.0 divisions.
2.0 divisions.
Ranges
Automatic Ranging
FREQUENCY
RANGE
1 Hz
10 Hz
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
10 MHz
100 MHz
150 MHz
LSD"
100 nHz
1
A*HZ
10
M
Hz
100 MHZ
1 mHz
10 mHz
100 mHz
1 Hz
10 Hz
100 Hz
Upranges at 100% of full scale; downranges at 9% of full
scale.
Downrange occurs at 90 MHz on 150 MHz range.
Full scale corresponds to the value given in the Range
column.
The maximum displayed value for any range is the
Range value minus the LSD value.
Performance requirement not checked in manual.
1-14

Table of Contents

Other manuals for Tektronix 2465B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 2465B and is the answer not in the manual?

Tektronix 2465B Specifications

General IconGeneral
BrandTektronix
Model2465B
CategoryTest Equipment
LanguageEnglish

Related product manuals